|
|
|
|
|
|
FS4000
Fire control panel FS4000 is designed for operating with conventional automatic fire
detectors and manual all point. The panel is produced in four versions
Functional Data.
Individual indication for each zone status and filed for labeling;
Control over the fire alarm lines and thr controllable outputs for fault condition
(short circuit or interruption ) and automatic reset
Detection for a removed fire detector and automatic reset ; |
|
|
|
|
|
|
|
FS5100
Adjustment of operating modes and parameters of each fire alarm line via
built-in keypad;
User-friendly dialogue menu for easy and convenient operation;
LCD display for visualization of check up modes and system setup;
LED indication for early warning of a break down or extreme conditions;
Ability to adress automatic fire detectors and manual call points in groups;
User-friendly test modes providing total control of the protected area; |
|
|
|
|
|
|
|
|
FS5200
Functional data Adjustment of operating modes and parameters of each fire alarm line via built-in keypad; LCD display with 4 lines for text inscribing for visualization of system checkup and setup modes; LED indication and sound signaling with built-in Text modes; Detecting activation of the automatic fire detectors and manual call points; Nonvolatile archive memory, saving the event type, and the moment of occurrence for up to256 events; |
|
|
|
|
|
|
|
FS5200E
The fire extinguishing control Panel is designated for fire protection, monitoring and control of system for active extinguishing gas, powder, aerosol, water, etc. After processing the signals from the automatic fire detectors and/or manual keys, the panel gives commands to the executive devices for Extinguishing, sounders, lamps, air conditioning and ventilation devices, etc . . . |
|
|
|
|
|
|
|
|
FS5200R
The Repeater is implemented to exchange data and commands with Remote Fire Control Panels. FS5200R: Receives data foe fault condition from Remote Control Panels; Receives data for fire condition from remote control panels; Displays information for the condition from Remote Control Panels; Executes control commands to the Remote Control Panels. The Repeater communicates via RS485 interface with Fire Control Panels FS5100, FS5200, FS5200E, FS5200R, and FS4000 of UniPOS Ltd. Data exchange is realized in compliance with a specialized protocol. The repeater can exchange data with PC or another intelligent device via the same interface. |
|
|
|
|
|
|
|
FS6000
The FS6000 Control panel has a modular organization. The basic configuration is equipped with one line Driver Module, which is capable to control 4 fire alarm lines. Each line can operate independently or a pair of lines be grouped in a loop. |
|
|
|
|
|
|
|
|
FS6000 - 6120L
Rate of Rise Heat Detector 6120L provides a reliable early warning of a fire condition with or without smoke emissions with minimum risk of false alarms. Detector 6120L activates upon a rate of rise in temperature, higher the specified or upon reaching the fixed temperature threshold of the protected area. The fire detector is available in three versions depending on the temperature class of activation in conformity with the European Standard EN54/5 (Class A2R or BR). Suitable for premises with normal ambient temperature, with out possible sudden changes. |
|
|
|
|
|
|
|
FS6000 - 6130L
Optical-Smoke Detector 6130L provides an early warning of detecting visible or concealed fire, responding to smoke emissions concentration. Upon reaching a fixed threshold level of smoke concentration, the detectors eneters Alarm condition. 6130L complies with the European Standard EN54/7 and by means of its double net structure is effectually protected against insects, high humidity and strong air flow. |
|
|
|
|
|
|
|
|
FS6000 - 6120 & 6130L
Combined Fire Detector 6120 & 6130L provides an early warning of a visible or concealed fire condition, responding to smoke concentration threshold or rate of rise temperature, higher than the specified one, or fixed temperature threshold exceeding. Fire detector 6120 & 6130L combine the advantages of optical smoke and rate of rise heat detectors with low delivery and installation expenses. |
|
|
|
|
|
|
|
FS6000 - 6150
Manual Call Point
Satisfies the requirement of the European Standard EN54/11 for a type A manual call point. A test option is provided by the
means of special test key. Upon manual call point activation the red LED is illuminated simultaneously. |
|
|
|
|
|
|
|
|
FS6000 - Instalation Outline Scheme
Of Addressable Fire
Alarm System FS 6000 |
|
|
|
|
|
|
|
Sereies 3000 - FD 3010
Fixed Temperature Heat Detector The fire detector provides a reliable early warning of a Fire condition with or without smoke release, when the ambient temperature of the protected area reaches a fixed temperature threshold. It is available in two versions (A2S or BS) depending on the temperature threshold of activation in accordance with the European Standard EN 54-5. The fire detector is suitable for premises with normal or high ambient temperature, with possible sudden changes. |
|
|
|
|
|
|
|
|
Sereies 3000 - FD 3020
Rate Of Rise Heat Detector The fire detector provides a reliable early warming of Fire condition with or without smoke release upon reaching a rate of rise of temperature, higher then the fixed temperature or upon reaching the maximum temperature threshold of the protected premises. It is available in two versions (A2SR or BR) depending on the temperature threshold of activation in accordance with the European Standard EN 54-5. The fire detector is suitable for premises with normal ambient temperature, without sudden changes. |
|
|
|
|
|
|
|
Sereies 3000 - FD 3030
Optical-Smoke Fire Detector The fire detector provides as reliable early warning of a Fire condition responding to fixed threshold smoke concentration, detected in the protected premises. The construction of the optic chamber and the technology used in manufacturing of the screen, provides high level protection against entering dust particles and insects and operation under strong air flow. The smoke sensitivity is in accordance with the European Standard EN 54-7 |
|
|
|
|
|
|
|
|
Sereies 3000 - FD 3060
Combined Fire Detection The fire detector provides a reliable early warning of a Fire condition, responding to fixed threshold smoke concentration or rate of rise of the temperature or fixed temperature threshold detected in the protected premises. It combines the advantages of type FD 3020 and type FD3030 and it is an attractive option due to decreased expenses for supply and installation. The fire detector complies with the requirement of the European Standard EN 54-5 (temperature class A2R) and EN 54-7 for the optic-smoke part. |
|
|
|
|
|
|
|
Sereies 3000 - FD 3040
Flame Fire Detector The fire detector provides a reliable early warning of a Fire condition upon detecting the infrared emission of the flame. It is suitable for premises, where other type of fire detectors are not applicable. The fire detector complies with the requirements of the European Standard EN 54-10. |
|
|
|
|
|
|
|
|
Sereies 3000 - FD 3050
Manual Call Point It is designated to release a signal for a Fire condition to the Fire Control Panel upon manual activation by breaking the glass on the place, signed with the arrows. The light indication for activating the manual call point is provided by a red LED. There is possibility for testing by a special key. Box color red. It satisfies the requirements of the European Standard EN54-11 for a type of manual call point. Options: extended back box for surface mounting; elastic element; protective cover; breakable seal. |
|
|
|
|
|
|
|
Sereies 8000 - FD 8010
Fixed Temperature Heat Detector The fire detector provides a reliable early warning of fire condition upon ambient temperature threshold. It is available in two versions (A2S or BS) depending on the temperature threshold of activation, and in accordance with the European Standard EN 54-5. The fire detector is suitable for premises with normal or high ambient temperature. with possible sudden changes |
|
|
|
|
|
|
|
|
Sereies 8000 - FD 8020
Rate of Rise Heat Detector The fire detector provides a reliable early warning of a Fire condition upon reaching a rate of rise of temperature, higher then the fixed temperature or upon reaching the maximum temperature threshold of the protected premises. It is available in two versions (A2R or BR) depending on the temperature threshold of activation in accordance with the European Standard EN 54-5. The fire detector is suitable for premises with normal ambient temperature, without sudden changes |
|
|
|
|
|
|
|
Sereies 8000 - FD 8030
Optical-Smoke Fire Detector The fire detector provides a reliable early warning of a Fire condition responding to fixed threshold smoke concentration, detected in the protected premises. Smoke sensitivities factory preset in accordance with the European Standard EN 54-7. The fire detector is controlled by a microprocessor. It operates with an improved algorithm for self-compensation of the optic chamber contamination, signaling the necessity for dusting the chamber . It is performed quickly due to the easy dismantling and assembling of the body cover. The optic chamber construction and the new technology used in manufacturing of the screen provides high level protection against entering dust particles and insects and operation under strong air flow. |
|
|
|
|
|
|
|
|
Sereies 8000 - FD 8060
Combined Fire Detector The fire detector provides a reliable early warning of a fire condition , responding to fixed threshold smoke concentration or rate of rise of the temperature or fixed temperature threshold detected in the protected remise . It combine the advantages of type FD 8020 and type FD 8030 and it is an attractive option due to decreased expenses for supply and installation. The fire detector complies with the requirements of the European Standard EN 54-5 (temperature class A1R) and EN 54-7 for the optic-smoke part. |
|
|