IFS7000


Functional Data
Fire Control Panel and all devices, connected in the loops are fully programmable;
Two-wire data exchange between the Control Panel and the devices;
Detection of Fault conditions: short circuit or loop interruption removed detector or swapped fire detectors, connection of the loop to the grounds;
Signal loops (with optional branch lines) for connecting of fire detectors, input or output modules, adapters, modules for automatic extinguishing;
One power loop for supplying of the executive devices (excluding IFS7002 with one signal loop);
 
 
IFS7002


One Signal Loop
 
 
 
IFS7002


Two Signal Loops
 
 
IFS7002


Four Signal Loops
 
 
 
FS6000


The FS6000 Control panel has a modular organization. The basic configuration is equipped with one line Driver Module, which is capable to control 4 fire alarm lines. Each line can operate independently or a pair of lines be grouped in a loop.
 
 
IFS7000 - FD7110


Fixed Temperature
Heat Detector
The fire detector provides a reliable early warning of a Fire condition upon ambient temperature reaching a fixed temperature threshold.
The temperature class (A1S, A2S or BS) is in compliance with the European Standard EN 54-5 and is programmable by Fire Control Panel IFS7002.
The fire detector is suitable for premises with normal and high ambient temperature, with possible sudden changes.
 
 
 
IFS7000 - FD7120


Rate of Rise
Heat Detector
The fire detector provides a reliable early warning of a fire condition upon reaching a rate of rise of the temperature or fixed temperature threshold in the protected premises.
The temperature class (A1R, A2R or BR) is in compliance with the European Standard EN 54-5 and is programmable by Fire Control Panel IFS7002.
The fire detector is suitable for premises with normal ambient temperature, without possible sudden changes.
 
 
IFS7000 - FD7130


Optical-Smoke
Fire Detector
The fire detector provides a reliable early warning of a fire condition responding to fixed threshold smoke concentration detected in the protected premises.
The smoke sensitivity (low, middle or high) is in compliance with the European Standard EN 54-7 and it is programmable by Fire Control Panel IFS7002.
The fire detector operates with an improved algorithm for self compensation of the public chamber contamination, signaling the necessity for dusting the chamber.
 
 
 
IFS7000 - FD7150


Manual
Call Point
It is designed to release a signal for a Fire condition to the Fire Control Panel IFS7002 upon manual activation by breaking the glass on the place assigned by the arrows.
The light indication for activation of the manual call point is provided by ared LED.
There is possibility for testing by means of the special key.
It satisfies the requirements of the European Standard EN 54-11 for A class manual call point and EN 54-17.
 
 
IFS7000 - FD7160


Combined
Fire Detectors
The fire detector provides a reliable early warning of a fire condition responding to fixed threshold smoke concentration or rate of rise of the temperature or fixed temperature threshold detected in the protected premises.
It combines the advantages of a type FD7120 and a type Fd7130 and it is an attractive option due to decreased expenses for supply and installation.
The temperature class (A1R, A2R or BR) and the smoke sensitivity (low, middle or high) are programmable by Fire Control Panel IFS7002 and they are in compliance with the European Standard EN54-5 and 54-7.
 
 
 
FS6000 - 6110L


Fixed Temperature
Heat Detector
6110L provides a reliable early warning of a fire condition with or without smoke emissions, with minimum risk of false alarm.
The fire detector activates upon exceeding a fixed temperature threshold in the protected area.
Fire detector 6110L is available in two versions depending on the temperature threshold of activation in accordance with the European Standard EN54/5 (Class A2S or BS).
The fire detector is suitable for premises with high and normal ambient temperature, with possible sudden changes.
 
 
FS6000 - 6120L


Rate of Rise
Heat Detector
6120L provides a reliable early warning of a fire condition with or without smoke emissions with minimum risk of false alarms.
Detector 6120L activates upon a rate of rise in temperature, higher the specified or upon reaching the fixed temperature threshold of the protected area. The fire detector is available in three versions depending on the temperature class of activation in conformity with the European Standard EN54/5 (Class A2R or BR).
Suitable for premises with normal ambient temperature, with out possible sudden changes.
 
 
 
FS6000 - 6130L


Optical-Smoke
Detector
6130L provides an early warning of detecting visible or concealed fire, responding to smoke emissions concentration.
Upon reaching a fixed threshold level of smoke concentration, the detectors eneters Alarm condition.
6130L complies with the European Standard EN54/7 and by means of its double net structure is effectually protected against insects, high humidity and strong air flow.
 
 
FS6000 - 6120 & 6130L


Combined
Fire Detector
6120 & 6130L provides an early warning of a visible or concealed fire condition, responding to smoke concentration threshold or rate of rise temperature, higher than the specified one, or fixed temperature threshold exceeding.
Fire detector 6120 & 6130L combine the advantages of optical smoke and rate of rise heat detectors with low delivery and installation expenses.
 
 
 
FS6000 - 6150


Manual
Call Point
Satisfies the requirement of the European Standard EN54/11 for a type A manual call point.
A test option is provided by the means of special test key.
Upon manual call point activation the red LED is illuminated simultaneously.
 
 
FS6000 - Instalation Outline Scheme


Of Addressable Fire Alarm System FS 6000
 
 
 
VIT 01


Functional Data
Signal level control;
Wireless devices tamper control;
Control over the wireless devices for battery status and power supply status;
Changing the parameters of the fire detectors;
Recognizing the type of devices and programming the user parameters;
Detection of a fault condition (short circuit or interruption) in the controllable outputs;
 
 
VIT 02


Router Router VIT02 performs the functions of a repeater (retransmitting the radio signals in the network) and controls conventional sounders or executive devices. It is power supplied by alternating voltage 220 V/ 5a Hz and has a built in backup battery, supporting its operation in case of fault in the external power supply.
 
 
 
VIT 10


Fixed Temperature
Heat Fire Detection
 
 
VIT 20


Rate of Rise Heat
Fire Detector
 
 
 
VIT 30


Optical - Smoke
Fire Detector
 
 
VIT 50


Manual
Call Point
 
 
 
VIT 60


Combined Fire
Detector